Atrial tachycardias originated at the left atrial appendage (LAA) are uncommon; often they are incessant and might induce tachycardiomyopathy, as discussed by Hillock et al. (Heart Rhythm;3(4)467-469, 2006). A case of a 21-year-old woman with incessant atrial tachycardia is presented, refractory to medical therapy, echocardiography showed global dilation with LV ejection fraction of 20%. After two failed endocardial ablations, an epicardial access was attempted. The earliest activation site was located at the tip of the epicardial aspect of the LAA. RFCA was successful at this site. The patient remains asymptomatic during a follow-up of 10 months; the ventricular function was completely recovered after 6 months (LVEF of 50%).
Delineate retrospectively and prospectively the incidence and characteristics of transient ST-segment elevation during transseptal puncture.
The study retrospectively evaluated 307 patients from January 1, 2015, to December 31, 2017, and prospectively evaluated 231 patients from January 1, 2018, to July 31, 2019.
The presence of ST-segment elevation was significantly higher in the prospective sample than in the retrospective sample (5.2% vs. 1.3%, p < 0.05). Between the two groups, there was no significant difference in age, sex, comorbidities, left atrial volume index, and the etiology of atrial fibrillation among patients with ST-segment alteration. In all patients, the ST-segment elevation was observed in the inferior wall derivations, except for one patient with ST elevation in lead I, AVL, V1-V4 during the septal puncture, associated with sinus bradycardia and reversed hypotension with intravenous fluids. Comparative analysis of the systolic and diastolic arterial pressure and the minimum heart rate during the phenomenon demonstrated more severity in the retrospectively evaluated population than in the prospective population. There was a significant association between the occurrence of ST-segment elevation > 2mm and the presence of symptoms. In these patients, coronary angiography showed no alterations. Atropine was administered to one patient who presented with junctional bradycardia after the puncture. This medication reversed the situation.
ST-segment elevation is a short-term phenomenon that can occur during transseptal catheterization without clinically evident symptoms. The catheter ablation procedure can be safely concluded despite the occurrence of the phenomenon.
ST-segment elevation is a short-term phenomenon that can occur during transseptal catheterization without clinically evident symptoms. The catheter ablation procedure can be safely concluded despite the occurrence of the phenomenon.
Graves' disease is the most common cause of hyperthyroidism. It results in accelerated tissue metabolism with multi-organ involvement ranging from cardiovascular to neuropsychological function. This results in a negative impact on the quality of life (QOL) of the individual patient. We aim to evaluate the psychometric properties of ThyPRO, a Thyroid-related Patient Reported Outcome questionnaire, and validate its use in our multi-ethnic Asian patients with Graves' hyperthyroidism.
Forty-seven consecutive Graves' hyperthyroidism patients answered the ThyPRO questionnaire at baseline and at 4 months after treatment initiation. Data were recorded for thyroid related symptoms and signs, thyroid function tests and thyroid volume. https://www.selleckchem.com/products/mivebresib-abbv-075.html We analyzed the internal consistency using Cronbach's alpha, construct validity by evaluating relationship between clinical variables and ThyPRO scales, ceiling and floor effects, and responsiveness of ThyPRO to treatment based on Cohen's effect size.
Correlations between individual scale scores and free thyroxine concentrations were moderate and statistically significant 0.21-0.64 (p< 0.05). There was high internal consistency between the items in this instrument, Cronbach's alpha > 0.7 for all scales. ThyPRO was responsive to the changes in QOL after treatment (Effect Size 0.20-0.77) in 9 of the 14 scales including the hyperthyroid symptoms and psychosocial scales (Tiredness, Cognitive complaints, Anxiety, Emotional susceptibility, Impact on Social, Daily and Sex life).
This study provides evidence that ThyPRO has satisfactory measurement properties in hyperthyroid Graves' disease patients in Singapore population with the potential to complement clinical care.
This study provides evidence that ThyPRO has satisfactory measurement properties in hyperthyroid Graves' disease patients in Singapore population with the potential to complement clinical care.Vertebral compression fracture is a deformity of vertebral bodies found on lateral spine images. To diagnose vertebral compression fracture, accurate measurement of vertebral compression ratio is required. Therefore, rapid and accurate segmentation of vertebra is important for measuring the vertebral compression ratio. In this study, we used 339 data of lateral thoracic and lumbar vertebra images for training and testing a deep learning model for segmentation. The result of segmentation by the model was compared with the manual measurement, which is performed by a specialist. As a result, the average sensitivity of the dataset was 0.937, specificity was 0.995, accuracy was 0.992, and dice similarity coefficient was 0.929, area under the curve of receiver operating characteristic curve was 0.987, and the precision recall curve was 0.916. The result of correlation analysis shows no statistical difference between the manually measured vertebral compression ratio and the vertebral compression ratio using the data segmented by the model in which the correlation coefficient was 0.929. In addition, the Bland-Altman plot shows good equivalence in which VCR values are in the area within average ± 1.96. In conclusion, vertebra segmentation based on deep learning is expected to be helpful for the measurement of vertebral compression ratio.Pleural lesions form a diagnostic challenge for the radiologist. Whereas lesions can be initially detected on chest radiographs, CT and MRI imaging are the imaging modalities of choice for further characterization. In a number of cases, imaging findings can be relatively specific. In general unfortunately, imaging findings are rather aspecific. Evolution and extrathoracic imaging findings are important clues toward the diagnosis.